An up to Seven Years Follow-up of a Telescopic Implant-Supported Fixed Partial Denture

Document Type : Case Report

Author

Assistant Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

Abstract
In this article, a telescopic implant- supported fix partial denture, and its seven years follow-up is reported. A 42 years old lady with edentulous free end space in the right quadrant of her lower jaw was refferd for construction of implant supported prosthesis. After implant insertion and osseointegration, the implants showed severe mesiodistal and buccolingual tiltation in the manner that might not be corrected by extensive preparation or using angled abutments. Telescopic copings were made to correct the angulation of the abutments and the path of insertion in order to allowed the construction of a suitable prosthesis. The prosthesis is functional and healthy after seven years follow-up.Key words: Telestcopic, Implant, Fix prosthesis

Volume 8, Issue 4 - Serial Number 4
42
Autumn 2007
Pages 82-88

  • Receive Date 30 November 2013
  • Accept Date 22 January 2019
  • First Publish Date 22 January 2019
  • Publish Date 01 December 2007